This is an early access version
Department for Collection of Blood and Blood Components, Polyclinic for Transfusion Medicine, University Clinical Centre Tuzla , Tuzla , Bosnia and Herzegovina
Department for Collection of Blood and Blood Components, Polyclinic for Transfusion Medicine, University Clinical Centre Tuzla , Tuzla , Bosnia and Herzegovina
Department for Collection of Blood and Blood Components, Polyclinic for Transfusion Medicine, University Clinical Centre Tuzla , Tuzla , Bosnia and Herzegovina
Department for Collection of Blood and Blood Components, Polyclinic for Transfusion Medicine, University Clinical Centre Tuzla , Tuzla , Bosnia and Herzegovina
Department for Collection of Blood and Blood Components, Polyclinic for Transfusion Medicine, University Clinical Centre Tuzla , Tuzla , Bosnia and Herzegovina
Department for Biochemistry, Polyclinic for Laboratory Diagnostics; University Clinical Centre Tuzla , Tuzla , Bosnia and Herzegovina
Aim Plateletpheresis is a specialized procedure that collects platelets from peripheral blood using a cell separator. Platelet concentrates obtained by apheresis have better content in terms of better functionality and viability of platelets, reduced risk of infection with blood transmissive viruses and HLA-sensitization. The aim of the study was to examine the influence of donors’ predonation haematocrit on the value of quality control parameters in the plateletpheresis product, to determine the frequency of adverse events and its relation to the predonation haematocrit value of donors.
Methods A retrospective analysis included the total number of performed plateletpheresis in the period between 1 January 2022 and 31 December 2023 at the Polyclinic for Transfusion Medicine in University Clinical Centre of Tuzla. Two groups of platelet donors with haematocrit <45% and haematocrit ≥45% and quality control parameters in both groups were compared.
Results A total of 73 donors with Hct<45%, and a total of 43 donors with Hct≥45% was found. The total volume of processed blood was significantly higher in the group of donors with Hct ≥45% (p<0.0001). The duration of the plateletpheresis was significantly longer in donors with higher haematocrit (p=0.003).
Conclusion The level of haematocrit in the donor significantly affected the duration of the procedure and the consumption of resources, but the quality of the final product did not deviate much from the values recommended by the International Society for Blood Transfusion (ISBT) and the American Association of Blood Banks (AABB).
Conceptualization, S.J.L.; Methodology, S.J.L. and A.Ž.; Supervision, S.J.L. and S.D.Ć.; Validation, S.J.L. and A.S.M.; Resources, S.D.Ć.; Investigation, A.Ž.; Formal Analysis, A.S.M.; Visualization, S.Č.S. and A.O.H. All authors have read and agreed to the published version of the manuscript.
No specific funding was received for this study
Authors retain copyright. This work is licensed under a Creative Commons Attribution 4.0 International License.
The statements, opinions and data contained in the journal are solely those of the individual authors and contributors and not of the publisher and the editor(s). We stay neutral with regard to jurisdictional claims in published maps and institutional affiliations.